CoolShirt Systems - 2004-0003 - Safetemp Cooling System

In stock
SKU
2004-0003
FSA Eligible
Add to Compare
$5,799.00
Shipping: Calculated at Checkout
Sold By: Each
Free Shipping free-shipping
2004-0003
FSA Eligible
Note: Please purchase based on product "Code". Images are provided by manufacturers and might not represent the product accurately.
Add to Wish List
Products Details

Oolshirt Systems Exclusive: Our Safe Temp Liquid Temperature Control System Offers The Most Aggressive Cooling & Warming Available, With Just A Touch Of The Temperature Touch Pad. Safe Temp Is Compatible With All Of Our Coolshirt Systems Cooling Garments, Blanket?s, Therapy Wraps & Can Accommodate 1 0r 2 Users. safe Temp Is Proudly Manufactured In The Usa With Medical Grade Components To Insure Safety & Ease Of Use. Set It & Forget It! features: easy To Use Dialing For Cooling And Warming In One Unit. safe Temp Can Accommodate 1 To 2 Users. medical Grade Ground Fault Power Cord. medical Grade Wheels With Locking On Rear heavy Duty Handles Rated 2x?s Weight Of Unit heavy Duty Stainless Steel Housing large 5.75 Liter Fluid Capacity 40 Db Max On Startup 19.5l X 13w X 20 22 To Top Of Handles. weight 90 Lbs extended Warranty Plans Availableoperating The Display: 1. Power Button: Press Power Button To Start The System. 2. Control On Indicator: This Light Indicates When The Unit Is On Or Off. 3. Heat Indicator: When The Set Point Is Set To 76 F/24 C Or Greater, The Control Will Be In Heat mode And The Heat Indicator Will Be Illuminated. 4. Fahrenheit / Celsius Selection Button: When The Control Is On, This Button Changes The system Units. 5. Cool Indicator: When The Set Point Is Set For 75 F/23 C Or Less, The Control Will Be In Cooling mode And The Cool Indicator Will Be Illuminated. 6. Digital Display: The Digital Display Shows Process Temperature, Set Point, Faults, And Program parameters As Required. 7. Down Button: The First Press Of This Button When The Control Is On Displays The Set Point For 5 seconds. The Second Press Of The Button While The Set Point Temperature Is Displayed Will Lower The set Point. This Button Is Also Used In Conjunction With The Up Button To Silence Faults. 8. Up Button: The First Press Of This Button When The Control Is On Displays The Set Point For 5 Seconds. the Second Press Of The Button While The Set Point Temperature Is Displayed Raises The Set Point. This button Is Also Used In Conjunction With The Down Button To Silence Faults.basic Operation: user Instructions: 1. Press The Power Button On The Display On The Front Of The Unit To Power The Unit On. 2. The Temperature Displayed Will Be The Current Temperature Of The Fluid In The System. 3. Press The Up Or Down Button Once To See The Set Point Temperature. (default Out Of The Box Is 60 F) 4. Adjust The Set Point Temperature To Desired Temperature. note: It Is Recommended To Pre-cool Or Pre-heat The System To Desired Temperature Before Putting A Load On the System. It Takes About 7 Minutes To Raise The Temperature 10 F In Heat Mode, And About 16 Minutes To Lower the Temperature 20 F In Cool Mode. heat Mode: when The Set Point Is Set For 76 F/2 C Or Above The Control Will Be In Heat Mode. The Compressor And fan Are Disabled And The Electric Heater Is Cycled To Maintain Set Point. cool Mode: when The Set Point Is Set For 75 F/23 C Or Lower, The Control Will Be In The Cool Mode. The Compressor and Fan Are Always Operating And The Heater Is Cycled To Maintain The Set Point Temperature. If There Is A Heater fault, Then The Compressor And Fan Will Cycle To Maintain The Set Point Temperature. Immediately After Ac Powerup Or After A Compressor Shutdown, The Compressor Will Not Be Allowed To Restart For 2 Minutes. The Fan Will Stay on For One Minute After The Compressor Turns Off. operating Sequence: push The Power Button To Turn On The Unit And Start The Sequence Of Operation. The Float Switch On The tank Must Make In Order To Start The Sequence. If Float Switch Is Not Made, It Means The Tank Does Not Have enough Fluid To Operate Safely. The Entire Unit Is Shut Down And The Buzzer Will Buzz Every 15 Seconds. ?lo? will Show On The Display. If Tank Has Enough Fluid (float Switch Makes), Then Pump-1 Will Start. Pump-1 Pumps the Process Fluid From The Tank Reservoir, Through An Evaporator And Back Into The Tank. After 15 Seconds From starting Pump-1, The Flow Switch Must Make. The Flow Switch Makes Sure Fluid Is Flowing Through The Evaporator and To Keep The System From Freezing. If The Flow Switch Does Not Make, Then The Entire Chiller Is Shut Down (all components Disabled) And The Buzzer Will Buzz Every 5 Seconds. ?flo? Would Show On The Display. If The Flow switch Makes, Then The Unit Can Operate In Either Heat Or Cool Mode. Once The Process Temperature Is Within 10 F Of The Set Point Temperature, Pump-2 Will Start. Pump-2 Pumps The Process Fluid From The Tank Reservoir through The Quick Disconnects And Coolshirt Vest. changing Set Point: press The Up Or Down Button To View The Process Set Point. Press The Up Or Down Button A Second Time while The Process Temperature Is Shown To Change The Value Between 45 F And 110 F. faults: the Buzzer Will Sound For 1 Second At The Intervals Listed Below When A Fault Occurs. display Shows Fault Buzzer Interval lo Low Level Switch Open 15 Seconds. flo Flow Switch Is Open 5 Seconds. lot Low Temperature Warning 10 Seconds. hit High Temperature Warning 10 Seconds. hf Heater Failure 5 Minutes sen Sensor Failure 3 Seconds

Customer Reviews
Write Your Own Review
Write a review of this product: Share your opinion with other customers
Your Rating
Product Information
More Information
Manufacturer CoolShirt Systems
Code 2004-0003
Sold By Each
HCPCS -
UPC -
GTIN -
Warehouse MultiWH
WHSXX COOSS
Compare Products
You have no items to compare.
Special Deals
Back to Top

CoolShirt Systems - 2004-0003 - Safetemp Cooling System

$5,799.00